Mount Calvary, Swansea

The three manual pipe organ at Mount Calvary Church in Swansea hadn’t been used in nearly 20 years. The Swell keyboard wasn’t working due to the pull down wires having corroded into the metal strip in the bottom of the windchest, and the Choir manual was unusable due to the rollers being badly adjusted. Most of the Great was working except that the pneumatic slider machines needed minor repairs.

All these were repairing within a week, when the organ was also treated for woodworm, and tuned.